  Datasheet File OCR Text:
  date revision title this specification sheet forms a part of the latest issue of raychem specification 44 and mil-w-81044 as applicable. conductor - silver-coated copper jacket - radiation-crosslinked, modified pvf 2 thickness: .004 .001 in. d wire, radiation-crosslinked, polyalkene-insulated, light weight, general purpose, 1000 volt part number 1 / wire size (awg) conductor stranding (number x awg) maximum diameter stranded conductor (in.) maximum resistance at 20c (ohms/1000ft.) table i. construction details maximum weight (lbs/1000 ft.) diameter (in.) .021.026 .033 .041 .052 .058 .072 .090 .118 .176 .218 .272 1.6 2.4 3.5 5.1 7.7 9.8 14.7 22.1 35.6 61.8 94.5 150. 38.424.3 15.1 9.19 5.79 4.52 2.88 1.90 1.19 .658 .418 .264 .040 .002.046 .002 .054 .002 .062 .002 .073 .003 .081 .003 .098 .004 .117 .004 .146 .004 .206 .006 .254 .007 .308 .008 19 x 3819 x 36 19 x 34 19 x 32 19 x 30 19 x 29 19 x 27 37 x 28 37 x 26 133 x 29133 x 27 133 x 25 44A0212-26-*44A0212-24-* 44A0212-22-* 44A0212-20-* 44A0212-18-* 44A0212-16-* 44A0212-14-* 44A0212-12-* 44A0212-10-* 44A0212- 8-* 44A0212- 6-* 44A0212- 4-* finished wire 2624 22 20 18 16 14 12 10 8 6 4 part number 1 / table ii. performance details bend testing mandrel diameter (inch) ( 3%) cold bend wrap immersion, life cycle and accelerated aging immersion, life cycle and accelerated aging cold bend 44A0212-26-*44A0212-24-* 44A0212-22-* 44A0212-20-* 44A0212-18-* 44A0212-16-* 44A0212-14-* 44A0212-12-* 44A0212-10-* 44A0212- 8-* 44A0212- 6-* 44A0212- 4-* .500 .500 .750 .750 1.00 1.00 1.50 2.00 3.00 3.00 4.00 5.00 .750 1.00 1.00 1.00 1.50 1.50 2.00 2.00 3.00 4.00 5.00 6.00 .250 .250 .250 .250 .375 .375 .500 .500 .750 .750 1.00 1.25 .375 .375 .375 .500 .500 1.00 1.00 1.50 2.00 3.00 3.00 3.00 1.002.00 2.00 3.00 3.00 4.00 4.00 4.00 4.00 5.00 8.00 8.00 weight (lb) ( 3%) 44A0212 12-7-05 specifica tion control dra wing primary insulation - radiation-crosslinked, extruded polyalkene page 1 of 2 this specification sheet takes precedence over documents referenced herein. referenced documents shall be of the issue in effect on date of invitation for bid. dimensions are in inches, and unless otherwise designated are nominal. 1 / colors and color code designators shall be in accordance with mil-std-681. other codes and suffixes may be added to the part number, as necessary, to capture any additionalrequirements imposed by the purchase order. users should evaluate the suitability of this product for their application. specifications are subject to change without notice. tyco electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to buyer. r wire & cable 501 oakside avenueredwood city, ca 94063-3800 phone: 1-800-227-8816 fax: 1-650-361-6297 ? 2005 tyco electronics corporation. all rights reserved.
specification control drawing page 2 of 2 scd number 44A0212 revision d wire ratings and additional requirements temperature rating: 150c maximum continuous conductor temperature voltage rating: 1000 volts (rms) at sea level accelerated aging: 300 2c for 6 hours identification legibility, 225 2c for 6 hours blocking: 150 2c for 24 hours color: white preferred flammability: 30 seconds (maximum); 3 in. (maximum); no flaming of facial tissue humidity resistance: insulation resistance, 5000 megohms for 1000 ft. (minimum) identification and striping durability: 125 cycles (250 strokes) (minimum), 500 g weight immersion: diameter increase 5% (maximum); no cracking, no dielectric breakdown insulation elongation and tensile strength: primary insulation, elongation, 150% (minimum) tensile strength, 2500 lbf/in2 (minimum) insulation flaws: primary insulation, sparktest, 2.0 kv (rms) impulse dielectrictest, 6.0 kv (peak) finished wire; sparktest, 4.0 kv (rms) at 3 khz impulse dielectrictest, 8.0 kv (peak) insulation resistance: 5000 megohms for 1000 ft. (minimum) life cycle: 200 2c for 168 hours low temperature-cold bend: -65 2c for 4 hours shrinkage: 300 2c, 0.125 in. (maximum) in 12 in., awg 26-12 300 2c, 0.250 in. (maximum) in 12 in., awg 10-4 smoke: 200 2c, no visible smokesurface resistance: 500 megohms-in. (minimum), both readings thermal shock resistance: 150 2c, 0.060 in. (maximum) voltage withstand test (post environmental): 3000 volts (rms), 60 hz, 5 minutes wicking: 2.25 in. (maximum) part number: the "*" in the part numbers on page 1 shall be replaced by color code designators. 1 / example: awg 20, white: 44A0212-20-9 1 / see footer section on page 1


▲Up To Search▲   

 
Price & Availability of 44A0212

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X